Issue 109549

Summary: No data available when editing filtered row set.
Product: Base Reporter: villeroy <villeroy>
Component: codeAssignee: marc.neumann
Status: CLOSED FIXED QA Contact: issues@dba <issues>
Severity: Trivial    
Priority: P2 CC: drewjensen.inbox, issues, mechtilde
Version: OOo 3.2Keywords: oooqa, regression, usability
Target Milestone: OOo 3.2.1   
Hardware: Unknown   
OS: All   
Issue Type: DEFECT Latest Confirmation in: ---
Developer Difficulty: ---

Description villeroy 2010-02-23 19:34:59 UTC
May be related to fixed #108390 or not.
http://user.services.openoffice.org/en/forum/viewtopic.php?f=39&t=27903
Comment 1 Mechtilde 2010-02-25 09:33:03 UTC
@ villeroy

please give us a step-by step description to be able to reproduce the problem
Comment 2 villeroy 2010-02-25 09:57:35 UTC
I filed this issue on behalf of another user.
- Using the latest OOo3.2 he opens a form bound to a boolean field in an
embedded HSQLDB like the one I attached in the linked forum topic.
- Toolbar "Form Navigation", button "Form-Based Filters" reloads a special view
of the form for criteria input. Another toolbar "Form Filter" pops up.
- Set the check box to boolean status True and click the first button on toolbar
"Form Filter" to apply the filter.
- You get a filtered form content where all the boolean values in the filtered
field are True.
- In my version 3.1.1 I can still edit the boolean field and set one of its
values to False whereas in his version 3.2 he gets the (partially German) error
message "Fehler beim Schreiben des aktuellen Datensatzes. No data is available"
Comment 3 drewjensen.inbox 2010-02-25 13:05:07 UTC
Confirmed w/ OOo3.2, Ubuntu

The forum entry has step-by-step wording, screen captures, attachment of a file
that shows the problem, from multiple users.

In my case  simply open a dataview window on a table with a boolean (can use the
attachment from the forum report) set a filter on the boolan column and then
edit a record.
Comment 4 Frank Schönheit 2010-02-25 14:33:53 UTC
sounds like a duplicate of issue 108412 to me. Ocke could probable confirm or
deny, but he's not available at the moment. Will try to reproduce the issue once
I have a recent build of CWS dba321a, where issue 108412 is fixed.
Comment 5 drewjensen.inbox 2010-02-25 15:00:03 UTC
yes it probably is - well at least there is an easy work around, just don't
upgrade to 3.2
Comment 6 Frank Schönheit 2010-02-26 09:01:52 UTC
not fixed in CWS dba321a, so it's not a duplicate. Assigning to Ocke. Target is
justified IMO, since it's a regression from 3.1.1.
Comment 7 ocke.janssen 2010-03-01 14:30:10 UTC
Fixed in cws dba321a.
Comment 8 ocke.janssen 2010-03-26 07:33:50 UTC
Please verify. Thanks.

For testing use the link above or a form with a sub form as described.
Comment 9 marc.neumann 2010-03-30 09:53:52 UTC
reassign to msc
Comment 10 marc.neumann 2010-03-30 09:54:49 UTC
verified in CWS dba321a

find more information about this CWS, like when it is available in the master
builds, in EIS, the Environment Information System:
http://eis.services.openoffice.org/EIS2/cws.ShowCWS?Path=DEV300%2Fdba321a
Comment 11 gghh 2010-05-16 07:35:16 UTC
Checked in OOo320m17,