Apache OpenOffice (AOO) Bugzilla – Full Text Issue Listing |
Summary: | No data available when editing filtered row set. | ||
---|---|---|---|
Product: | Base | Reporter: | villeroy <villeroy> |
Component: | code | Assignee: | marc.neumann |
Status: | CLOSED FIXED | QA Contact: | issues@dba <issues> |
Severity: | Trivial | ||
Priority: | P2 | CC: | drewjensen.inbox, issues, mechtilde |
Version: | OOo 3.2 | Keywords: | oooqa, regression, usability |
Target Milestone: | OOo 3.2.1 | ||
Hardware: | Unknown | ||
OS: | All | ||
Issue Type: | DEFECT | Latest Confirmation in: | --- |
Developer Difficulty: | --- |
Description
villeroy
2010-02-23 19:34:59 UTC
@ villeroy please give us a step-by step description to be able to reproduce the problem I filed this issue on behalf of another user. - Using the latest OOo3.2 he opens a form bound to a boolean field in an embedded HSQLDB like the one I attached in the linked forum topic. - Toolbar "Form Navigation", button "Form-Based Filters" reloads a special view of the form for criteria input. Another toolbar "Form Filter" pops up. - Set the check box to boolean status True and click the first button on toolbar "Form Filter" to apply the filter. - You get a filtered form content where all the boolean values in the filtered field are True. - In my version 3.1.1 I can still edit the boolean field and set one of its values to False whereas in his version 3.2 he gets the (partially German) error message "Fehler beim Schreiben des aktuellen Datensatzes. No data is available" Confirmed w/ OOo3.2, Ubuntu The forum entry has step-by-step wording, screen captures, attachment of a file that shows the problem, from multiple users. In my case simply open a dataview window on a table with a boolean (can use the attachment from the forum report) set a filter on the boolan column and then edit a record. sounds like a duplicate of issue 108412 to me. Ocke could probable confirm or deny, but he's not available at the moment. Will try to reproduce the issue once I have a recent build of CWS dba321a, where issue 108412 is fixed. yes it probably is - well at least there is an easy work around, just don't upgrade to 3.2 not fixed in CWS dba321a, so it's not a duplicate. Assigning to Ocke. Target is justified IMO, since it's a regression from 3.1.1. Fixed in cws dba321a. Please verify. Thanks. For testing use the link above or a form with a sub form as described. reassign to msc verified in CWS dba321a find more information about this CWS, like when it is available in the master builds, in EIS, the Environment Information System: http://eis.services.openoffice.org/EIS2/cws.ShowCWS?Path=DEV300%2Fdba321a Checked in OOo320m17, |