Issue 98916

Summary: Scrollbar does not include the final step - truncates value
Product: Calc Reporter: norm1710 <ian.t.price>
Component: codeAssignee: AOO issues mailing list <issues>
Status: CONFIRMED --- QA Contact:
Severity: Trivial    
Priority: P3 CC: cno, issues
Version: OOo 3.0   
Target Milestone: ---   
Hardware: PC   
OS: All   
Issue Type: DEFECT Latest Confirmation in: ---
Developer Difficulty: ---
Attachments:
Description Flags
calc sheet showing the scroll bar truncating max value
none
calc sheet showing the scroll bar truncating max value
none
test document where the bug does not show up none

Description norm1710 2009-02-05 12:11:46 UTC
Using a scrollbar form control values are entered for default, min, max, small
change and large change.  One set of figures I used was:

Default: 160
Min: 21
Max: 160
Small Chg: 1
Large Chg: 5

The scrollbar will only scroll to 159.  On testing, it always knocks 1 off the
last step value, e.g. if the above small or large change value was 3 or 5, it
would still only go to a max of 159.
Comment 1 norm1710 2009-02-05 12:13:29 UTC
Created attachment 59951 [details]
calc sheet showing the scroll bar truncating max value
Comment 2 norm1710 2009-02-05 12:14:48 UTC
Created attachment 59952 [details]
calc sheet showing the scroll bar truncating max value
Comment 3 cno 2009-04-30 21:29:41 UTC
Can confirm the described behaviour in 3.1RC2

Mind: when the xlsis opened, it initallly shows 160 for the scrollbar in D7.
But when once changed, 159 stays the maximum
Comment 4 cno 2009-04-30 21:47:52 UTC
@norm1710: does your bug document has a special history?
When I create a new ods + scrollbar, the set Max: 160 indeed will be
visible/reached.
Comment 5 cno 2009-04-30 21:51:33 UTC
Created attachment 61937 [details]
test document where the bug does not show up