Issue 123286 - maximum and minimum related to date and time validity accepts invalid date and time
Summary: maximum and minimum related to date and time validity accepts invalid date an...
Status: CONFIRMED
Alias: None
Product: Calc
Classification: Application
Component: ui (show other issues)
Version: 3.4.0
Hardware: Other Windows, all
: P3 Normal (vote)
Target Milestone: ---
Assignee: AOO issues mailing list
QA Contact:
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2013-09-18 16:29 UTC by Akriti
Modified: 2013-09-19 06:57 UTC (History)
3 users (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments
invALID (201.65 KB, image/png)
2013-09-18 16:29 UTC, Akriti
no flags Details
Sample document (7.91 KB, application/x-vnd.oasis.opendocument.spreadsheet)
2013-09-19 05:12 UTC, Rainer Bielefeld
no flags Details

Note You need to log in before you can comment on or make changes to this issue.
Description Akriti 2013-09-18 16:29:44 UTC
Created attachment 81569 [details]
invALID

In validity dialog
1)Select time->In 'Data' select 'between'. In minimum field enter 23,34 and maximum field enter 4555?12 .Press Ok

Error Noticed 1: maximum and minimum field accept invalid input.There should be  error state set to the field when user enter invalid input .

2) Reopen the validity dialog again and check the min and max value

Error Noticed 2: Data entered in min and max altered to some invalid number
Comment 1 Rainer Bielefeld 2013-09-19 05:09:18 UTC
More or less Reproducible with  "AOO 4.0.1 – German UI / German locale  [AOO401m5(Build:9714)  -  Rev. 1523756 2013-09-16 20:50:21]" on German German WIN7 Home Premium (64bit)", Common 4.0-dev User Profile.

It seems we have 2 (possibly related) problems here.

a) Acceptance of invalid Values in Validity dialog.
That problem already does exist for me with English OOo 3.1.1 with English Locale setting. I can copy/paste the values from report, and they will be accepted, but "23,34" is not a number for that Locale.

b) Change to strange values
This also is already reproducible for me with above mentioned 3.1.1. (after save - close - reopen):

Input Value      After Close-Reopen
23,34            552:00:00
4555?12          34,4555?12
Comment 2 Rainer Bielefeld 2013-09-19 05:12:31 UTC
Created attachment 81576 [details]
Sample document

You can do your own tests in yellow cells range.

Still Reproducible with  "AOO 4.1.0-Dev – English  UI / German locale - [AOO410m1(Build:9750)  -  Rev. 1523968 - 2013-09-18]" on German WIN7 Home
Premium (64bit)", own separate user profile.
Comment 3 Rainer Bielefeld 2013-09-19 06:57:15 UTC
I think this one is related to or DUP of "Bug 55161 - Error message for wrong input (date with format of different locale) in validity dialog "