Issue 78629 - RPT: printed format differs to inputted format in datetime fields
Summary: RPT: printed format differs to inputted format in datetime fields
Status: CLOSED DUPLICATE of issue 78504
Alias: None
Product: Base
Classification: Application
Component: code (show other issues)
Version: recent-trunk
Hardware: All All
: P3 Trivial (vote)
Target Milestone: ---
Assignee: ocke.janssen
QA Contact: issues@dba
URL:
Keywords: new_implementation
Depends on:
Blocks:
 
Reported: 2007-06-18 17:08 UTC by christoph.lukasiak
Modified: 2013-08-07 15:45 UTC (History)
1 user (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments

Note You need to log in before you can comment on or make changes to this issue.
Description christoph.lukasiak 2007-06-18 17:08:43 UTC
0. open a new database
1. create a table with a datetime field (containing value: '31.12.99 00:01')
2. open the report designer and bind it to the table
3. open the add field container and d&d the fields in design area
4. execute the report

-> printed result from datetime field: '1999-12-31 00:01:00.0'

=> the format has changed
=> the time became a float
Comment 1 christoph.lukasiak 2007-06-18 17:09:26 UTC
set keyword 'new_implementation'
Comment 2 Frank Schönheit 2007-07-02 10:09:30 UTC
The Report Designer iTeam decided that this is no show stopper for the first
release, and no "should be fixed if possible at all". targeting to "not
determined" for the moment.
Comment 3 ocke.janssen 2007-07-20 10:58:57 UTC
Duplicate one.

*** This issue has been marked as a duplicate of 78504 ***
Comment 4 ocke.janssen 2007-07-20 10:59:17 UTC
Closing it.