Issue 70483 - No keyboard focus after changing view
Summary: No keyboard focus after changing view
Status: ACCEPTED
Alias: None
Product: Impress
Classification: Application
Component: ui (show other issues)
Version: OOo 2.0.4
Hardware: All All
: P3 Trivial (vote)
Target Milestone: ---
Assignee: AOO issues mailing list
QA Contact:
URL:
Keywords:
Depends on:
Blocks:
 
Reported: 2006-10-16 16:59 UTC by ftack
Modified: 2017-05-20 11:08 UTC (History)
1 user (show)

See Also:
Issue Type: DEFECT
Latest Confirmation in: ---
Developer Difficulty: ---


Attachments

Note You need to log in before you can comment on or make changes to this issue.
Description ftack 2006-10-16 16:59:51 UTC
When the working view is changed by clicking one of the tabs
(Normal/Outline/Notes/Handout/Slide sorter), the new view does not have keyboard
focus (except for outline). Steps to illustrate the issue:

1) Open a new presentation and insert a few slides.
2) Click the Slide Sorter tab: the Page Up/Down keys won't work unless you first
click on a slide
3) Click on the Normal view: idem

The same happens when another view is selected using the View menu. There is no
way to restore keyboard input than by clicking the mouse
Comment 1 wolframgarten 2006-10-17 07:35:53 UTC
Reproducible. Reassigned.
Comment 2 groucho266 2006-10-17 08:54:49 UTC
Hotkeys still work, the menu for instance, is still accessible.

A workaround is to press F6 and then Shift+F6.  This puts the focus back into
the center pane (after switching views).
Comment 3 Martin Hollmichel 2007-11-09 17:18:44 UTC
set target from 2.x to 3.x according to
http://wiki.services.openoffice.org/wiki/Target_3x
Comment 4 ftack 2010-08-18 13:17:04 UTC
This appears to work correctly in OOo 3.20. Please close this issue.
Comment 5 Marcus 2017-05-20 11:08:42 UTC
Reset assigne to the default "issues@openoffice.apache.org".